
CaburISLElectrical cabinets AC/DC cabinets
ISL SERIES SWITCHBOARDS
Single-phase DC/AC switchboards
Inside each switchboard the protection and manoeuvre circuits of the photovoltaic field strings and the AC section of the inverter are already wired: to complete the system, the installer simply has to position and fix the ISL switchboard and connect the photovoltaic strings and the inverter to it.
The ISL Series switchboards are composed of two distinct and separate subsystems: AC switchboard and DC switchboard.
-
Switchboard, with a compact and elegant design, suitable for installation both outdoors and indoors thanks to its IP65 protection rating. Equipped with UV-resistant transparent door.
-
Panel-mounted photovoltaic connectors allow quick and safe connection, and are also provided with plugs to ensure an IP65 degree of insulation.
-
20kA surge arresters. available in 600Vdc and 1000Vdc versions for the best coordination with the actual system voltage
-
600Vdc or 1000Vdc rotary disconnector depending on the system voltage, ideal for the safe protection and disconnection of strings. Equipped with padlock handle.
-
Differential magnetothermal switch, single-phase or three-phase, class A or AC 300mA, with 6kA or 10kA breaking capacity.
-
20kA AC surge arrester, available in single-phase or three-phase versions.
Model ISL-0101-CA-06
- 1 DC input from the PV array
- 1 DC output to the inverter
- Max. input voltage 600V
- DC connections via Cabur Line 4 connectors Up to 1 MPPT can be managed
- Class A differential circuit breaker 6kA circuit breaker
- AC and DC surge protectors
- Compliant with IEC EN 61439-2
Model ISL-0101-CA-10
- 1 DC input from the PV array
- 1 DC output to inverter
- Max. input voltage 1000V
- DC connections via Cabur Line 4 connectors Up to 1 MPPT can be managed
- Class A differential circuit breaker 6kA circuit breaker
- AC and DC surge protectors
- Compliant with IEC EN 61439-2
Model ISL-0201-CA-06
- Up to 2 DC inputs from the PV array
- 1 DC output to the inverter
- Max. input voltage 600V
- DC connections via Cabur Line 4 connectors
- Up to 1 MPPT Class A differential circuit breaker
- 6kA thermal-magnetic circuit breaker AC and DC overvoltage limiters
- Compliant with IEC EN 61439-2
Model ISL-0201-CA-10
- Up to 2 DC inputs from the PV array
- 1 DC output to the inverter
- Max. input voltage 1000V
- DC connections via Cabur Line 4 connectors
- Up to 1 MPPT Class A differential circuit breaker
- 6kA thermal-magnetic circuit breaker AC and DC overvoltage limiters
- Compliant with IEC EN 61439-2
Model ISL-0202-CA-06
- Up to 2 DC inputs from the PV array
- Up to 2 DC outputs to the inverter
- DC connections via Cabur Line 4 connectors
- Max. input voltage 600V
- Up to 2 MPPT can be managed Class A differential circuit breaker
- 6kA thermal-magnetic circuit breaker AC and DC overvoltage limiters
- Compliant with IEC EN 61439-2
Model ISL-0202-CA-10
- Up to 2 DC inputs from the PV array
- Up to 2 DC outputs to the inverter
- DC connections via Cabur Line 4 connectors
- Max. input voltage 1000V
- Up to 2 MPPT can be managed Class A differential circuit breaker
- 6kA thermal-magnetic circuit breaker AC and DC overvoltage limiters
- Compliant with CEI EN 61439-2